BIS Certification for Electric Hot Plates – IS 302 (Part 1): 2024
Electric Hot Plates are ubiquitous in homes, hostels, canteens, cloud kitchens, labs, and small commercial setups. Because they convert high electrical power into heat at the countertop, they present shock, fire, and burn risks if not built and tested correctly. India now mandates BIS (ISI) certification for Electric Hot Plates so only safe, conforming products reach the market. This guide gives you everything needed to comply, pass on the first attempt, and outrank competing pages.
The Safety of Household, Commercial and Similar Electrical Appliances (Quality Control) Order, 2025) makes BIS certification compulsory for appliances intended for household, commercial or similar use. The Order enforces IS 302 (Part 1): 2024 / IEC 60335-1:2020 and applies up to 250 V (single-phase) and 480 V (other, incl. DC/battery). It comes into force on 19 March 2026, with extended dates for MSMEs. Electric Hot Plates are explicitly named in the Order’s illustrative list of covered products.
Implementation dates under QCO 2025
1. ) General manufacturers: 19 March 2026
2. ) Small enterprises: 19 June 2026
3. ) Micro enterprises: 19 September 2026
Certification scheme & mark
Products must bear the Standard Mark (ISI) under a licence issued by BIS in Scheme-I of Schedule-II of the BIS (Conformity Assessment) Regulations, 2018. BIS is both the certifying and enforcing authority. Non-compliance is punishable under the BIS Act, 2016.
Exemptions
1. ) Goods made exclusively for export.
2. ) Up to 200 units/year imported only for R&D by appliance manufacturers (not for sale; scrap disposal allowed; year-wise records required).
3. ) Declared pre-implementation stock manufactured/imported by a BIS-certified/applicant manufacturer may be sold for up to six months post implementation, subject to declaration to BIS.
Scope: What counts as an Electric Hot Plate?
1. ) Portable or tabletop electric heating plates used to heat cookware directly (solid plate, coil, infrared/ceramic top).
2. ) Single or multi-plate variants for household, hostel, office pantry, café, and similar use.
3. ) Rated voltages within QCO limits (250 V single-phase; 480 V others incl. DC/battery).
Note: “Warming Plates and Similar Appliances” are also listed separately in the QCO; if your product is a dedicated food-warming surface with lower power density and different construction, evaluate the closer functional description before filing. Electric Hot Plates themselves are specifically listed.
Applicable Standard
1. ) IS 302 (Part 1): 2024 – Household and Similar Electrical Appliances — Safety — Part 1: General Requirements (harmonized with IEC 60335-1:2020).
This Part 1 is the mandatory baseline under QCO 2025. If BIS later notifies a Part 2 product-specific standard for hot plates, you must meet that in addition to Part 1. (As of the QCO 2025 notification, Part 1 is the cited mandatory standard.)
Type Tests typically checked for Hot Plates (as per IS 302-1 framework)
BIS-recognized labs evaluate representative models for:
1. ) Protection against electric shock (insulation, earthing continuity)
2. ) Input power & current (nameplate conformity)
3. ) Heating / temperature rise (accessible surfaces, windings, cord set)
4. ) Abnormal operation (thermostat failure/single-fault, run-dry where applicable)
5. ) Leakage current & dielectric strength
6. ) Moisture resistance (humidity, ingress depending on construction)
7. ) Mechanical strength (enclosure, terminals, mounting)
8. ) Stability & mechanical hazards (tip-over, sharp edges, guards)
9. ) Supply connection & external flexible cords (cord anchorage, flexing)
10. ) Screws & connections; clearances/creepage distances; heat & fire resistance
11. ) Marking & instructions durability (label rub test, manual content)
Routine/acceptance tests at factory level should mirror critical safety checks: earthing continuity, HV/IR, functional thermostat cut-out checks, visual & marking verification.
Marking & User Information (what must appear)
1. ) ISI Standard Mark with licence number (CM/L-xxxxxxx).
2. ) Rated voltage/frequency, input power, class of protection, model/type, manufacturer’s name/address/brand.
3. ) Safety instructions (hot surface warnings), correct cookware use, ventilation/clearance, cleaning, and service guidance.
4. ) If detachable cords or special plugs are used, include compatibility notes.
Documents Required (typical)
1. ) Manufacturing licence & plant layout, process flow chart.
2. ) List of production & in-house test equipment (with calibration).
3. ) Product specs: circuit diagram, BoM, ratings, critical components (thermostats, cords, plugs).
4. ) QC plan (incoming, in-process, final), routine test records formats.
5. ) Brand/trademark proof, packaging artwork with ISI mark placement.
6. ) Sample(s) and test request to BIS-recognized lab.
BIS Certification Process (Scheme-I)
1. ) Manakonline application (factory details, models, documents).
2. ) Type testing at a BIS-recognized lab (IS 302-1).
3. ) Factory inspection (capability, controls, test facilities).
4. ) Evaluation & grant of licence (ISI mark authorized).
5. ) Post-licence surveillance (market samples, factory audits).
BIS is the certifying & enforcing authority.
Fees & Cost Estimate (indicative)
QCO does not prescribe fees. Below are industry-typical ranges to budget properly (actuals vary by model count, lab tariffs, travel, and production scale).
1. ) Application fee: 1,000
2. ) Processing fee: 25,000 (one-time)
3. ) Lab testing: 45,000 – 90,000 per model (power rating & construction dependent)
4. ) Factory inspection: 7,000 + auditor travel & lodging at actuals
5. ) Annual licence fee: 1,000
6. ) Marking fee: typically ?0.50–?1.00 per unit (volume-linked; finalized by BIS)
I. ) Total (India): 85,000 – 1.4 lakh for one model, excluding internal QA setup.
II. )FMCS (foreign factories): typically USD 4,000–7,000 due to overseas inspections/logistics.
Timelines (realistic planning)
1. ) India manufacturers: 30–45 days from complete file + passed test report.
2. ) Foreign manufacturers (FMCS): 3–6 months depending on inspection scheduling & shipping lead times.
For Importers & Foreign Manufacturers
1. ) Overseas factories must obtain BIS licence under FMCS before import.
2. ) If you import as a brand owner while using a contract manufacturer, the factory must hold the licence for the certified models.
3. ) Use the QCO exemptions carefully (R&D 200 units/year not for sale).
Post-Certification Obligations
1. ) Use ISI mark exactly as licensed on product, rating label, packaging, and manual.
2. ) Maintain routine tests & records; calibrate instruments on schedule.
3. ) Inform BIS before any critical component change or design revision; seek model inclusion as needed.
4. ) Support BIS surveillance: market sample testing, factory audits.
5. ) Renew licence on time (up to 2-year validity per cycle).
Common Non-Conformities (and how to avoid them)
1. ) Excess surface temperatures at handles/top: validate thermostat/cut-out placement; verify cookware contact.
2. ) Cord anchorage failure: upgrade grommets/clamps; conduct 100% pull tests.
3. ) Insulation/clearance shortfalls near heater terminals: redesign creepage; use higher CTI materials.
4. ) Label rub-off: switch to heat-resistant rating labels; test durability.
5. ) Sparse instructions: add warnings (hot surface symbol), cookware size limits, ventilation, and cleaning guidance.
Benefits of BIS Certification
1. ) Legal market access from March 2026.
2. ) Consumer trust and retailer acceptance via ISI mark.
3. ) Lower liability risk (documented safety compliance).
4. ) Competitive edge in e-commerce and tenders.
FAQs for BIS Certification for Electric Hot Plates
1) Is BIS certification mandatory for Electric Hot Plates in India?
Yes. The 2025 QCO mandates ISI-marked appliances; Electric Hot Plates are explicitly listed.
2) Which standard applies?
IS 302 (Part 1): 2024 / IEC 60335-1:2020 (General safety).
3) What are the voltage limits covered?
Up to 250 V single-phase and 480 V for other, incl. DC/battery appliances.
4) When does it take effect?
19 March 2026 (with later dates for small/micro enterprises).
5) Which BIS scheme is used?
Scheme-I (ISI Mark) under BIS (Conformity Assessment) Regulations, 2018.
6) Are any items exempt?
Export-only goods; 200 units/year for R&D (not for sale); declared pre-implementation stock sale up to six months.
7) Who enforces this?
BIS is both certification and enforcement authority; contraventions are punishable under the BIS Act, 2016.
8) Do I need in-house test equipment?
Yes, to sustain routine tests and surveillance readiness (HV/IR, earthing, temperature checks).
9) What does the ISI label include?
Standard Mark with licence no., ratings, model, manufacturer/brand, and required warnings.
10) What if my product is a low-power warming surface?
If it’s a warming plate, it is separately named in the QCO list; still under IS 302-1 per the Order. Evaluate the most accurate product category and file accordingly.
For More Blogs Click Here
- BIS Certification for Slicing Machines
- BIS Certification for Electric Sieving Machines
- BIS Certification for Electric Shredders
- BIS Certification for Electric Potato Peelers
- BIS Certification for Electric Noodle Makers
- BIS Certification for Electric Knives
- BIS Certification for Electric Knife Sharpeners
- BIS Certification for Electric Graters
- BIS Certification for Electric Grain Grinders